Brand name:DOCO
Model:DC-C5A, DC-C8A, DC-C10A, DC-15A, DC-20A, DC-25A
Cooling capacity:2.178kw-93kw
Refrigerant:R22, R407, R410
Certificate:ISO, CE
Compressor brand:Copeland, Panasonic, Hitachi, Daikin
Warranty:1year
Application:Widely used in injection mold,laser marking welding equipment,vacuum coating machine,packaging machine,semiconductor equipment etc.

Enquiry

 Performance 

The housing of the chiller is designed with the three-dimensional sheet-metal software Solidworks and processed by the imported precision-numerical-control sheet-metal equipment, and the shell surface is well treated with the environmental electrostatic powder coating, which makes the chiller be elegant and durable. The condenser adopts the thickened corrugated window-opening aluminum fin with copper tubing, which makes high efficiency on heat exchange, environmental and power-saving.
 
Built-in high and low voltage, overload, delay, flow and other multiple protection devices ensure the equipment operation more stable. The world famous brand compressors (Panasonic, Daikin, Copeland) and refrigeration electronic control components (Danfoss, Emerson, Siemens, etc.) are selected for the equipments. The general model control accuracy is ±1℃ and the special model can reach ±0.5℃.
 
Multiple refrigeration circuits can be set up and each circuit can run separately, which meets the demand of variable load, favours power saving, improves the safety and stability of equipment operation, and satisfies the severe requirements for temperature in various industrial production. The normal temperature model is 5-25℃ and the low temperature model is from -25℃ to -5℃. Non-standard models can be customized based on customers’ requirements.

Application 

The air cooled chillers are widely used in injection mold, laser marking welding equipment, vacuum coating machine, packaging machinery, semiconductor equipment, welding machine electrode, plasma cutting machine, spindle cooling of PCB drilling machine, etc. to protect the precision equipments and improve production efficiency.

 Product Configuration 


 
 Safeguard 


 
 Technical Parameters 
 
Model Item DC-C1A DC-C2A DC-C3A DC-C5A DC-C8A-D DC-C10A-D DC-C12A-D DC-C15A-T DC-C20A-F DC-C25A-D DC-C30A-T
Horsepower HP 1 2 3 5 8 10 12 15 20 25 30
Refrigerating
Capacity
kcal/h 2390 4730 7181 12900 20640 26660 28810 38700 53320 65360 79980
KW 2.78 5.5 8.35 15 24 31 33.5 45 62 76 93
Temperature
Control Range℃
5-25℃
Power Supply 220V 50HZ 1PH 380V 50HZ 3PH
Compressor
Power(kw)
0.83 1.7 2.5 4 3*2 4*2 4.6*2 4*3 4*4 10*2 8*3
Refrigerant R22 ( Environmental Refrigerant R407 and R410 are optional )
Condensor Type Air cooled condenser(corrugated open-window aluminum foil radiating fin with copper tube inside,20% increase
in heat dissipation efficiency)
Fan Type Large-flow and Low-Noise Axial Fan Motor

Evaporator
Type Coil evaporator inside water tank(stainless steel plate heat exchanger or shell tube dry evaporator are optional)
Water tank
volume
20 35 50 62 125 125 130 240 300 350 400
Chilling
water pump
Power KW 0.37 0.37 0.37 0.37 0.75 0.75 0.75 1.5 1.5 2.2 2.2
Chilling water flow  0.6-0.8 0.9-1.3 1.3-1.8 2.6-3.5 4.2-5 5.1-6 6-6.8 7.5-9 10-12 11-13 15-18
Chilling Water Inlet/outlet
Caliber (inch)
1/2" 1/2" 1/2" 1" 1-1/2" 1-1/2" 1-1/2" 2" 2" 2-1/2" 2-1/2"
Dimensions Length mm 605 775 925 1155 1250 1250 1250 1800 1860 1860 2100
Width mm 485 555 575 655 755 755 755 1050 1100 1100 1250
Height mm 876 908 1012 1082 1550 1550 1550 1750 1930 1930 2150
Safety Protection Delay protection, flow protection, compressor overheating protection, refrigerant high and low pressure protection, overcurrent protection, phase sequence / phase deficiency protection, overload protection, overtemperature protection, etc.


 Technical Specifications: 

1. Model number specification: e.g. DC-C10A-D, “DC” indicates Doco company code, “C” indicates chiller, “10” indicates 10 horsepower, “A” indicates air cooled chiller, “D” indicates dual system with two compressors, “T” indicates three compressors, “F” indicates four compressors.
2. *Compressor power: *2indicates two compressors working and two independent refrigerating systems.
3. Refrigerating capacity parameter basis: the temperature of inlet and outlet chilled water is 12℃ / 7℃ and the temperature of inlet and outlet cooling air is 30 ℃ / 35℃.
4. Working ranges: the temperature range of chilling water is from 5℃ to 35℃, the temperature difference between inlet and outlet chilling water is from 3℃ to 8℃, the ambient temperature can not be higher than 40℃, and the high-temperature model should be selected when the ambient temperature is higher than 40℃.
5. We reserve the right to revise the above information without prior notice.


 The applications 
 

The Application of Chillers in Vacuum  Casting Equipment
The Application of Chillers in Vacuum Casting Equipment

The Application of Chillers in Bearing Steel Ball Industry

The Application of Chillers in Chemical Reactor Equipment




Copy right © 2019 Wuxi DOCO Refrigeration Equipments Co., Ltd. All Reserved